Hello! Welcome to the Shenzhen Bojia Communication Equipment Co., Ltd website!

Website MapImmediately consult中文网站

National consultation hotline:+86-13823379730

The Application of GPS Antenna in the Field of Intelligent Meter Reading

Information sourced from:internet Published on:2023-06-21

Basic functions of GPS antenna application in the field of intelligent meter reading:
1. Remote meter reading can be fixed by a microcomputer and can be read anytime and anywhere through a mobile phone. Easy to query< Br/> 2. The prepaid management manager can directly send the electricity bill to the on-site GSM-3Y device through a computer or mobile phone based on the prepaid bill or bank transfer bill, thereby accumulating the remaining electricity bill and stopping electricity management. That is, centralized management of computers and the use of mobile phones by regional power workers< Br/> 3. When the remaining 20%, 10%, and 5% of the prepaid electricity fees are paid by the user, a mobile text message is sent to notify the user to continue with the electricity fee. After using the prepaid electricity fee, a control signal is output to suspend non electricity costs, and at the same time, a power outage is prompted to the user and the host. After payment, the power management personnel will send the electricity (quantity) to the on-site GSM-3Y, and then automatically restore power supply. Under special circumstances, the host can issue special commands to complete remote control and power failure< Br/> 4. Rate and fee management: Users can preset peak, valley, flat, multiple peak times, and multiple rate management based on their needs. Computers and mobile phones can be used to stop adjusting the electricity prices during time periods and seasons< Br/> 5. Auxiliary functions can alarm the status of on-site measurement installation, such as opening of the measurement box, power failure, phase loss, restoration of power notification, switch contact indication or leakage maintenance< Br/> 6. The device provides bidirectional control signal output. 240 v20a control. The one-way output adopts a relay that usually closes the contact, and the double output is a 500ms closing signal, suitable for energy-saving contactors< Br/> 7. Alarm status: External sensor switch contact, contact closed, no alarm, contact open alarm< Br/> 8. Cost free electricity management: After users use prepaid electricity, they output a power outage control signal, suspend electricity use, and provide power outage information to users in a timely manner without charging. When the cost of electricity is still being supplied, the output signal is output every 100 yuan< Br/> 9. Phase loss alarm: when the connection mode is three-phase four wire, any phase or two phases lose voltage, the phase of the three-phase power supply corresponds to the missing phase. When the connection method is three-phase three wire, due to the internal triangular connection, when the AC phase is missing, phase B loses phase AB and phase C loses phase BC< Br/> 10. Power outage alarm: When the three-phase loses phase, cut off the power supply< Br/> 11. Restore power supply, alarm power failure, and restore three-phase power supply< Br/> 12. When exceeding the load, the output power exceeds the set power of a reading cycle of 3 meters (approximately 15 points)< Br/> 13. GPRS protocol No. 698. National network: Q/GDW376. 1-2009 standard.
cp_code[1]:C1_Share_copyright null